EN ISO 10993-17:2023 Biological evaluation of medical devices - Part 17: Toxicological risk assessment of medical device constituents (ISO 10993-17:2023)

ISO 10993-17 specifies the process and requirements for the toxicological risk assessment of medical device constituents to be used within the biological evaluation of the final product (described in ISO 10993-1). It includes the methods and criteria used to assess if exposure to a chemical constituent is without appreciable harm.

The process described in this standard is intended to apply after chemical characterization compositional profiling is performed as required by ISO 10993-18, and thus a toxicological risk assessment of either the compositional information, extractable data or leachable data is required to conclude if the risks related to the constituents are acceptable or not.

The process described in ISO 10993-17 is not intended to apply to circumstances where the toxicological risk has been estimated by other means, such as:

- constituents, excluding cohort of concern or excluded chemicals, that are present or extracted at an amount representative of patient exposure below a relevant, toxicologically-based reporting threshold.

- a new or changed medical device for which chemical or biological equivalence has been established with an existing biocompatible or clinically established medical device.

The process described in ISO 10993-17 is also not applicable to:

- medical device constituents that do not contact the body,

- all biological risks applicable to a medical device provided that the chemical exposure is unchanged,

- active pharmaceutical ingredients of device-drug combination products or biologic components of device-biologic combination products as additional regulatory considerations may apply,

- exposure to a particular chemical constituent that arises from sources other than the device, such as food, water, or air.

The text of ISO 10993-17:2023 has been approved in Europe as EN ISO 10993-17:2023 without any changes.

______

Fonte: ISO

Collegati

Certifico s.r.l.

Sede: Via A. De Curtis, 28 - 06135 Perugia - IT
P. IVA: IT02442650541

Tel. 1: +39 075 599 73 63
Tel. 2: +39 075 599 73 43

Assistenza: +39 075 599 73 43

www.certifico.com
info@certifico.com

Testata editoriale iscritta al n. 22/2024 del registro periodici della cancelleria del Tribunale di Perugia in data 19.11.2024