ID 20836 | 24.11.2023 / Attached

Confined space means a space that has any of the following characteristics:

- limited openings for entry and exit; 
- unfavourable natural ventilation;
- not designed for continuous worker occupancy.

It includes, but is not limited to, boilers, pressure vessels, cargo holds, cargo tanks, ballast tanks, double bottoms, double hull spaces, fuel oil, lube oil, sewage-tanks, pump-rooms, compressor rooms, cofferdams, void spaces, duct keels, inter-barrier spaces and engine crankcases.  
...

Oxygen-deficient atmosphere.

The health effects and consequences because of lack of oxygen in a confined space are listed in the table below. These effects will take place without any warning such as odour or physical symptoms.

Health effects from lack of oxygen
O2 level Effects
22 % Oxygen enriched atmosphere
20.8% Normal level – Safe for Entry (± 0.2%)
19.5%  Oxygen deficient atmosphere
16% Impaired judgement and breathing
14% Rapid fatigue and faulty judgement
11% Difficult breathing and death in a few minutes

Lack of oxygen leads very quickly to unconsciousness and death. Lack of oxygen may be a problem in all kinds of confined spaces, it is therefore considered as the most dangerous factor when considering dangers in a confined space.

The oxygen level in a confined space can decrease because of work being done, such as welding, cutting, or brazing; or, it can be decreased by certain chemical reactions like: rusting, paint drying or through bacterial action (fermentation).

In tanks and/or voids of complicated geometry with high possibility of "pockets of atmosphere" with low O2-content, and where rescue operations may be difficult, the use of a portable oxygen meter with audible alarm is strongly recommended.

Inert gas, N2 and exhaust

Inert gas is a non-reactive gas used to prevent possible explosive atmosphere from different cargo vapours.
On Oil Tankers the most common inert gas is the exhaust from oil fired boilers, main- or auxiliary engines. On Chemical Tankers the most common inert gas is nitrogen.
Pure nitrogen is not poisonous itself, but it causes displacement of the natural breathing environment.
Exhaust contains hundreds of chemical compositions. Main components are: carbon monoxide, oxygen, nitrogen, water vapour, sulphur dioxide, nitrogen oxides and hydrocarbons. The exhaust as described above may cause reduced lung capacity and increased respiratory in addition to irritating mucous membrane in eye, nose and throat.
Total dilution of oxygen by another gas, such as carbon dioxide, will result in unconsciousness, followed by death.

Bulk Cargoes

A number of bulk cargoes may cause low level of oxygen in the cargo hold. This is mainly with cargoes like vegetables, grain, timber, forestry products, iron metals, metal sulphide concentrates and coal.

Some bulk cargoes may oxidize which may result in reduced level of oxygen, poisonous gases, or self ignition. Other bulk cargoes may produce poisonous gases without oxidation, especially when they are wet.
....

Contents

1. Definitions
1.1 Confined Space
1.2 Competent person
1.3 Responsible person
1.4 Marine Chemist

2. General Hazards

3. Confined space – Safe entry policy
3.1 General
3.2 Entering confined spaces adjacent to loaded tanks
3.3 Entering confined spaces adjacent to inerted tanks

4. Confined space - Safe entry procedure
4.1 General
4.2 Entering confined spaces adjacent to loaded tanks on double hull tankers – additional requirements

5. Permit-to-work and permit-to-enter

6. Testing of the atmosphere
6.1 General 
6.2 Testing for oxygen
6.3 Testing for flammable atmosphere
6.4 Testing for toxic atmospheres 
6.5 Testing instruments 

7. Preparation for Entering Confined Spaces
7.1 Ventilation
7.2 Isolation of Space
7.3 Standby / rescue

8. Personal Protection Equipment (PPE)  ANNEX Guidelines for safe entry of Confined Spaces
...

add attached

Collegati

Certifico s.r.l.

Sede: Via A. De Curtis, 28 - 06135 Perugia - IT
P. IVA: IT02442650541

Tel. 1: +39 075 599 73 63
Tel. 2: +39 075 599 73 43

Assistenza: +39 075 599 73 43

www.certifico.com
info@certifico.com

Testata editoriale iscritta al n. 22/2024 del registro periodici della cancelleria del Tribunale di Perugia in data 19.11.2024